Smoke Sensor

../../../../_images/smoke_sensor.png

Overview

Based on the MQ-2 gas sensor, used for detecting smoke, liquefied gas, methane, butane, and other gas concentrations in the atmosphere. The higher the gas concentration, the greater the AO output.

Technical Specifications

Operating voltage: VCC 3.3V -5V

Module dimensions: 24*48mm

Mounting: 2 plastic building block compatible through-holes

Data type: Analog sampling value

Pin Definition

Pin

Definition

GND

Ground

VCC

Power

AO

A nalog sampling value

NC

Not connected

Example Code

Special reminder: After powering on, the sensor needs to preheat for about 20 seconds for stable measurement data. Sensor heating is normal because it contains an internal heating wire.

The mPython Board OLED display shows the real-time smoke analog value measured by the sensor. When the measured value exceeds 2000, the mPython Board RGB LED lights up.

from mpython import *

from bluebit import GasSensor

gasSensor_0 = GasSensor(0)

import time
while True:
    oled.fill(0)
    oled.DispChar(str(str('Smoke analog: ') + str(gasSensor_0.get_raw_val())), 0, 0, 1)
    oled.show()
    if gasSensor_0.get_raw_val() > 2000:
        rgb.fill((int(255), int(0), int(0)))
        rgb.write()
        time.sleep_ms(1)
        time.sleep(1)
    else:
        rgb.fill( (0, 0, 0) )
        rgb.write()
        time.sleep_ms(1)
../../../../_images/smoke_sensor1.png