4. Serial Port Protocol

Version History

Version

Date

Description

v1.0

2023-08-20

Initial version

v1.1

2023-09-15

Added string command type

Protocol Overview

This protocol defines two UART communication formats: - Basic control command (data type 0x01) - String transmission command (data type 0x02)

Common Parameters

Parameter

Value

Baud rate

1152000 bps

Data bits

8 bits

Stop bits

1 bit

Parity

None

Frame header

0xAA 0xBB

Checksum

Low 8 bits of the sum

Basic Control Command (0x01)

Frame Structure

  Main controller
+--------------+-----------+----------+---------+------------+----------+
| Frame header | Data type | Main cmd | Sub-cmd | Data field | Checksum |
+--------------+-----------+----------+---------+------------+----------+
| 0xAABB       | 0x01      | 1 byte   | 1 byte  | 8 bytes    | 1 byte   |
+--------------+-----------+----------+---------+------------+----------+

  AI Camera response
+--------------+-----------+----------+---------+------------+----------+
| Frame header | Data type | Main cmd | Sub-cmd | Data field | Checksum |
+--------------+-----------+----------+---------+------------+----------+
| 0xBBAA       | 0x01      | 1 byte   | 1 byte  | 8 bytes    | 1 byte   |
+--------------+-----------+----------+---------+------------+----------+

Function Description

AI_Uart_CMD(uart, cmd=0, cmd_type=0, cmd_data=[0] * 8)
Send a basic control command

Parameters: - cmd: main command byte (see 5.1 command list) - cmd_type: sub-command type - cmd_data: must be an 8-byte list

String Command (0x02)

Frame Structure

+--------------+-----------+----------+---------+------------+---------------+----------------+----------+
| Frame header | Data type | Main cmd | Sub-cmd | Extra data | String length | String content | Checksum |
+--------------+-----------+----------+---------+------------+---------------+----------------+----------+
| 0xAABB       | 0x02      | 1 byte   | 1 byte  | 3 bytes    | 1 byte        | N bytes        | 1 byte   |
+--------------+-----------+----------+---------+------------+---------------+----------------+----------+

Function Description

AI_Uart_CMD_String(uart, cmd=0xFE, cmd_type=0xFE, cmd_data=[0] * 3, str_buf='')
Send a string command

Parameters: - cmd_data: must be a 3-byte list - str_buf: UTF-8 encoded string (length calculated automatically)

Command Reference

Basic Command List

Main cmd

Sub-cmd

Command name

Data field format

0x01

0xFF

Camera initialization

None

0x02

0x01

Set parameter - integer

[Param ID(1B), Value(4B), Reserved(3B)]

0x02

0x02

Set parameter - float

[Param ID(1B), Value(4B), Reserved(3B)]

0x03

0x00-0xFF

Function control

See function control sub-command table (Appendix A)

String Command List

Main cmd

Sub-cmd

Command name

String format description

0xFE

0x00

Plain text message

UTF-8 encoded text

0xFE

0x01

Debug info

“[DEBUG]” + text content

0xFD

0x00

JSON control command

Standard JSON format

Serial Port Commands

../../../../_images/uart_comm.png

AI Camera Response Data Format

Code Examples

Basic Command Example

# Query device status
AI_Uart_CMD(uart1, cmd=0x01)

# Set parameter
AI_Uart_CMD(uart1, cmd=0x02, cmd_type=0x01, cmd_data=[0x01,0x00,0xFF])

String Command Example

# Send a normal message
AI_Uart_CMD_String(uart1, str_buf="Hello World")

# Send a JSON control command
AI_Uart_CMD_String(uart1, cmd=0xFD,
                  cmd_data=[0x01,0x02,0x03],
                  str_buf='{"led":1,"beep":0}')

Checksum Calculation

Checksum = sum(all data bytes) & 0xFF

Algorithm implementation:

def calc_checksum(data):
    return sum(data) & 0xFF

Error Handling

  • A frame with a checksum error should be discarded

  • An erroneous command received should return the 0xEE error code

AI Camera Response Frame Format

+--------------+-----------+-------------+------------+---------------+----------+
| Frame header | Data type | Status code | Extra data | Response data | Checksum |
+--------------+-----------+-------------+------------+---------------+----------+